Syphilis Screening (EIA)

Test Name:CAPTIA™ Syphilis (T. pallidum)-G
Test Methodology:Qualitative detection of IgG antibodies to T. pallidum by automated enzyme immunoassay
Test to be Performed:Syphilis Screening (EIA)
CPT:86780
Reflex Testing Criteria:Syphilis EIA is the first step in the reverse algorithm for syphilis testing. Repeatedly reactive results will be reflexed to RPR titer.
Pre-Approval Required:N/A
Accepted Specimens:At least 1 mL of non-hemolytic, non-icteric, non-lipemic serum in SST (preferrable). EDTA or citrated plasma samples are acceptable.
Specimen Stability:Serum samples should be tested within 5 days of collection. Optimum storage: 2-8°C. For samples that require longer than 5 days storage, serum must be removed from the red cells and stored at -20°C or below. Sera may be frozen and thawed only once.
Plasma samples should be tested within 48 hours. Do not freeze plasma.
Storage/Transport Conditions:Specimens should be stored and transported at 2-8ºC. Sufficient frozen cold packs in an insulated cooler can be used to maintain this temperature.
Turnaround Time:7 business days
Reference Range:Non-reactive
Comments:Reactive treponemal IgG antibody test results usually remain reactive for a lifetime; therefore, antibody indices cannot be used to determine response to therapy.